Venta De Terrenos Agricolas En El Salvador, California State Fair Art Entry 2022, Ssrs Filter Expression Wildcard, Ridgid Table Saw Serial Number Location, Articles S

Monitoring Accessory Configured But Still Won't Link? Ginlong Solis solar inverters Preamble. After you connect verify the WIFI stick sees the inverter. Verify the RSSI (signal strength) is higher than 15%. Select Network, fill in the IP address assigned by the router/network administrator, 1: Connect LAN stick to operational inverter to provide power to LAN stick. Some of our partners may process your data as a part of their legitimate business interest without asking for consent. Solis datalogger installation instructions APP Enso Circle Space 2.1K subscribers Subscribe 84K views 3 years ago This instructional video shows you how to setup the WIFI monitoring on your. Solis S1-W4G-ST WiFi & Cellular Data Logger Set Up Guide; Solis S3-WIFI-ST Wi-Fi Data Logger Setup Guide; Solis DLS-W WiFi Data Logger Installation Guide; Solis Cellular Data Logger Installation Guide; Solis DLS-C Cellular Data Logger - Carrier Compatibility; Replacing a Solis Data Logger; WiFi password changed These limits are designed to provide reasonable protection against harmful interference in a residential installation. Router has a firewall blocking the data 5. The replacement is working brilliantly. Solis DLS-G GPRS Datalogger setup and troubleshooting, Solis Data Logger Server Information - wyjtki w firewall'u, Pylon US2000C/US3000C Battery - CAN Failure - No Battery - Deutsch, Solis Data Logger Server Information - firewall exceptions. 1. Monitoring Accessory Configured But Still Won't Link? RHI-1P(5-10)K-HVES-5G Operation & Troubleshooting, Arc-Fault Alarm Troubleshooting for RHI-1P(5-10)K-HVES-5G, Advanced Hybrid DSP Issues - Replacing the DSP Board, Export Power Set and FailSafe Configuration, MET_Comm-FAIL and RS485 Fail Troubleshooting, Modbus Communications for RHI-1P(5-10)K-HVES-5G-US, Solis String-Level RSD Troubleshooting Procedures, Solis-(75-100)K-5G Tigo MLRSD Transmitter Disabling, Solis-1P(5-10)K-4G SunSpec MLRSD Transmitter Disabling, RHI-1P(5-10)K-5G SunSpec MLRSD Transmitter Disabling, RHI-1P(5-10)K-5G Tigo MLRSD Transmitter Disabling, Solis S1-W4G-ST WiFi & Cellular Data Logger Set Up Guide, Solis S3-WIFI-ST Wi-Fi Data Logger Setup Guide, Solis DLS-W WiFi Data Logger Installation Guide, Solis Cellular Data Logger Installation Guide, Solis DLS-C Cellular Data Logger - Carrier Compatibility, WiFi Stick Not Working With WiFi Extender Network. Victor is the author of this solution article. I will ask AGL for a replacement. A Solis 5K inverter is used here as an example.Please follow the instructions below:Install the datalogger: NOTEOnly rotate the black circle, not the sliver cover. Internal DC Short: In the inverter head, or the wirebox? We use cookies to try and give you a better experience in Freshdesk. my Solis app has stopped giving info since about 1 am with message "Current plant offline, Please check network connection of plant device", is it just the wifi (or has the whole system gone down) and will re-booting the system put it right. If the plant has multiple data loggers, please click View Plant. With permission, you can test the firewall by removing the firewall for 5 minutes to see if the communication with the remote server changes to pingable. No, Modified on: Tue, Oct 4, 2022 at 2:54 PM. Then plug theWifiData Logger into the port and be sure to secure it by tightening the black connector. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. Gua rpida de instalacin del sistema de monitoreo para Mxico y Centro Amrica. Note: the logger is unable to connect to anyWiFinetwork that uses symbols in the password. Press the button for 5 seconds to reset2 red lights are on and off at the same time. Shows the connection status between the datalogger and the server. Once you've connected to the "AP" network, return to, and then look for the home network that you wish to connect the logger to. RHI-1P(5-10)K-HVES-5G Operation & Troubleshooting, Arc-Fault Alarm Troubleshooting for RHI-1P(5-10)K-HVES-5G, Advanced Hybrid DSP Issues - Replacing the DSP Board, Export Power Set and FailSafe Configuration, MET_Comm-FAIL and RS485 Fail Troubleshooting, Modbus Communications for RHI-1P(5-10)K-HVES-5G-US, Solis String-Level RSD Troubleshooting Procedures, Solis-(75-100)K-5G Tigo MLRSD Transmitter Disabling, Solis-1P(5-10)K-4G SunSpec MLRSD Transmitter Disabling, RHI-1P(5-10)K-5G SunSpec MLRSD Transmitter Disabling, RHI-1P(5-10)K-5G Tigo MLRSD Transmitter Disabling, Solis S1-W4G-ST WiFi & Cellular Data Logger Set Up Guide, Solis S3-WIFI-ST Wi-Fi Data Logger Setup Guide, Solis DLS-W WiFi Data Logger Installation Guide, Solis Cellular Data Logger Installation Guide, Solis DLS-C Cellular Data Logger - Carrier Compatibility, WiFi Stick Not Working With WiFi Extender Network. Thanks for your help, my data logger looks like it is faulty. Is there a trick to setting it up properly that I am missing? 1. If you would like to change your settings or withdraw consent at any time, the link to do so is in our privacy policy accessible from our home page.. 2. Victor is the author of this solution article. Establecer el estndar de red personalizado Definido por usuario, Valores de la configuracin USER DEF para red 240v y 480v, Procedimiento de actualizacin remota de firmware, Reduccin de la potencia de salida del inversor Solis monofsico, Instalacin de cable RS-485 con conector circular, Configuracin de la direccin en inversor trifsico, Restablecer WiFi-Stick a la configuracin de fbrica, Registro de usuario final al sistema de monitoreo. Connect the data logger to the corresponding 4-pin COM port of the inverter. I haven't been able to log onto it after many attempts. Then plug the Wifi Data Logger into the port and be sure to secure it by tightening the black connector. Monitoring Accessory Configured But Still Won't Link? 125K Multi-Input Inverter: No Paralleled DC Strings Allowed! Wi-Fi trensmitting power: 802.11b/g/n: +20dBm/+18dBm/15dBm (Max) Data collection intervals: 5 minutes (adjustable:1-20 minutes) Preferences setting: Web server/Serial AT instruction. This equipment should be installed and operated with a minimum distance of 20cm between the radiator & your body. If you run through the setup wizard and are still having problems I suggest you contact them. Step 5: Long press the Reset button for 5 seconds until the yellow and green LEDs are quickly flashing. on solis S3-WIFI WiFi Stick Datalogger Installation Guide, solis GPRS Stick Datalogger Instruction Manual. If its not broadcasting conduct this procedure - https://www.youtube.com/watch?v=nUjcDcY8-Ws - If that doesn't fix the issue of it broadcasting please contact your local Solis Service Center and RMA the WIFI Stick. ), Get the latest developments in Ginlong Solis, Copyright@2019 Ginlong Technologies All Rights Reserved, Solis_datasheet_S3-GPRS,WiFi-ST_IND_V2.0_2022_08.pdf. I'm having the same issue, just tried setting it up but says it's offline, light on the stick is red, anything I should be checking? View the total data of your PV plant. Any changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. Open a web browser and enter "10.10.100.254" into the address bar 4. The decision to disable the feature was made via a poll last year. If its not pingable, the password is good, the signal strength is good then login to the router and check the customers firewall protections. Solis inverter - Ginlong data logger Solar, Batteries & Technology Questions and discussion about solar, batteries, and other renewable energy technology Solis inverter - Ginlong data logger Comet 08-05-2018 09:43 PM 6 Replies 1 Like 45040 Views Hi We have just had a solar system installed. You can learn more about what kind of cookies we use, why, and how from our Privacy policy. Verify the WIFI stick is broadcasting by looking for the WIFI transmitter AP_XXXXXXXXXX in your WIFI SSID connections. Please follow the instructions below: Step3: Use your mobile phone to send a text message to the SIM card in the stick. You can learn more about what kind of cookies we use, why, and how from our Privacy policy. Connect your laptop to the Solis Wi-Fi network - this has a name which looks like "AP-xxxxxxxxx" 3. Solis is one of the oldest and largest global string inverter specialists that manufactures single-phase inverters, three phase inverters and energy stroage inverters for residential, commercial and utility scale PV systerms . Solis Plant Offline, Please Check Devices and Netwo. cordless phone, concrete wall, PV panel and metal wall, to ensure the communication quality. Yes my data logger also glows red as well, does appear to be a LED keepalive in the unit to show its still transmitting data to the mothership. Step2: Connect the datalogger to the corresponding 4-pin COM port of the inverter. If it is set to one verify the WIFI stick has a good connection to the inverter. Technician check pins 1 and 2 for 5VDC, 3. Reliability Safety Capacity WiFi Data Logger. Sorry we couldn't be helpful. In general you want to ensure the router is not blocking the IP address from the WIFI stick. Go to your web browser - Input 10.10.100.254 4. Step 5: Scan the SN number of the datalogger or manually input it.Note: Scan the datalogger SN, NOT the inverter SN. Help us improve this article with your feedback. The